January 05, 2016

SME partnership promotes motor customisation


~ CP Automation teams up with Spanish motor expert VASCAT ~

Supply and repair specialist CP Automation and motor manufacturer VASCAT are working together to challenge the way companies commission industrial motors. Through electrical and mechanical customisation, VASCAT adapts each motor’s design to reflect the requirements of specific applications. Together, CP Automation and VASCAT can offer a complete motor and inverter drive solution even for the most complex industrial projects.  

VASCAT and CP Automation are calling for engineers to opt for customised motors instead of off-the-shelf solutions to help improve the performance and accuracy of the application and increase overall system productivity.

“Our two companies see eye to eye when it comes to commissioning a new drive system,” explained John Mitchell, global business development manager of CP Automation. “In most cases, choosing a standard motor will involve some kind of compromise. However, by commissioning a custom-made motor instead, a company can significantly reduce the size of the inverter it uses, which results in considerable energy and cost savings in the long run.”

“The VASCAT-CP Automation collaboration means customers in the UK and internationally benefit from no minimum order quantities, short product delivery times and stronger technical support,” continued Xavier Palomar, sales and marketing manager of VASCAT. “Because VASCAT’s motors are not commodity products, we prefer to work with technically-oriented partners that can help us offer a complete drive system solution for different application across industry sectors.”

VASCAT and CP Automation have already worked together on projects to retrofit old machines and installations in the steel sector and replace older generation motors with more efficient ones, built to the same specifications.

VASCAT offers solutions for low and high-speed motors. VASCAT’s gearless high-torque low-speed synchronous motors allow the elimination of gearboxes, belts and pulleys by directly coupling the motor to the load. VASCAT direct drive motors are available with outputs from 2kW to 340kW in the 100RPM to 1000RPM range, which makes them ideal for applications in renewable energy, converting, testing systems, metal processing lines and more.

VASCAT’s high-speed asynchronous vector motors ensure the high dynamic performance required by power train and engine dynamometers, energy recovery and test rig applications.

CP Automation specialises in the supply, repair and field service for industrial electronic boards, PLCs, AC and DC drives, resistors and inverters.

December 16, 2015

Don’t let harmonics get you down

Bookmark and Share
~ Top tips for choosing the right harmonic filter ~

How to choose the right harmonic filter
In 1976, it was discovered that the bacteria causing Legionnaires disease, an atypical strain of pneumonia, had always been present in water, but it was the precise temperature of the water in heating, ventilation and air conditioning systems that facilitated the bacteria’s maximum reproduction levels. This is just one example of the unintended consequences of technology. 

A similar and more recent story comes from the world of industry and features the growing problem of harmonic currents and utility level voltage distortion, as a result an increasing number of non-linear loads in industrial and commercial environments. Here, John Mitchell, global business development manager of supply, repair and field service specialist, CP Automation, shares his top tips for companies that want to commission or replace harmonic filters.

Why are harmonics a problem?
Non-linear loads include common office equipment like computers, printers and battery chargers, as well as industrial equipment like fluorescent lighting, variable speed drives (VSDs) and transformers. A load is considered non-linear if its impedance changes with the applied voltage. This change means the current drawn by the non-linear load will not be sinusoidal even when it is connected to a sinusoidal voltage. Non-sinusoidal loads contain harmonic currents that interact with the impedance of the power distribution system to create voltage distortion and power quality problems.

Voltage distortion can cause significant damage to plant or building equipment, as well as the mains power supply. Common symptoms of high harmonics levels include motor vibration, voltage notching, electromagnetic interference and overheating, all of which are harmful for equipment and result in heat loss and increased maintenance and energy costs.

Harmonic filters do what they say on the tin: they remove harmonics and correct the phase of the fundamental currents, converting non-linear loads into linear ones. So far, so good; however, when it comes to commissioning the right harmonic filter for your specific application, things can get tricky.

Active versus passive
The first thing you should decide is whether you need a passive or an active harmonic filter. The traditional option is an electro-mechanical or semiconductor controlled passive filter, used to minimise power quality problems in the network. These filters operate mainly on a fixed basis and are tuned to a harmonic order close to the order to be eliminated.

Often new equipment is specified to meet a THID%, but the problem for many plants is they do not know how bad their site is already. It’s almost like fixing a sticky plaster to a deep wound. Instead, companies should look at what is physically and commercially viable in the long term.

When making a decision, you can also consider a mixed solution. By fitting passive filters on many applications, you should be able to add a smaller active solution, which can save a lot of costs depending on the plant.

One drawback of passive filters is that they are most efficient when the load is operating above 80%.

On the other hand, active harmonic filters continuously monitor the network and inject exactly the right amount of compensation current when it is needed. The filter compensates the harmonic current or voltage drawn by each load. This allows current waveform to be restored instantaneously and lowers current consumption.

For installations in which current load changes constantly, active harmonic filters work best. They can filter harmonics over a wide range of frequencies and adapt to any type of load.

Regardless of what type of harmonic filter you decide to use, make sure it has the relevant UL certifications for the environment in which it's going to run. If unsure, you should always refer to an expert.

Space and current rating requirements
In environments where space is an issue, such as commercial buildings in urban spaces, data centres, the mining industry or a plant floor, it is important to consider the best fit for the purpose in choosing a solution.

Modularity can play a key role in your decision, as it refers to the degree to which a system’s components can be separated and recombined. Apart from space savings, modularity also means cost savings because it makes installation and maintenance more straightforward, reducing the need for many connectors and cables. With active harmonic filters, if one of the modules has a fault, a technician can shut down and repair or replace it, while the rest of the filter continues to run in reduction mode. This way, harmonic levels are kept under control even during maintenance.

One final benefit of modular harmonic filters is that their capacity can be increased or decreased depending on how the plant’s systems change, which can save significant costs in the long run.

No heat excess
Another memorable thing about 1976 was the particularly hot summer that year. Harmonic currents can induce additional heating in generators, which can have a negative effect on the entire system. In the long run, harmonics can also lead to heating of busbars, cables and equipment, cause thermal damage to induction motors and generators and thermal tripping of safety devices, like fuses or sensors in breakers.

In this already sizzling environment, any additional source of heat needs to be thought through. Luckily, some active filters, like the Comsys ADF series, produce up to a third less heat than others due to their switching techniques of the insulated-gate bipolar transistors (IGBTs). Equally, the REVCON RHF Series of passive filters offer up to 99.5% efficiency.

When comparing a filter, be it active or passive, you should look closely at the total cost of ownership for the end user. After all heat loss is a direct cost in energy bills. This is particularly important on the shop floor, in marine and offshore applications or any other environments where space and heat is particularly precious.

Intuitive software
To make users’ lives easier, active harmonic filters come with intuitive software and remote data access. This means authorised users can access real time information and see live harmonics data by using a PC, laptop, tablet or smartphone with internet access. Most modern harmonic filters have web based tools that require no special software installation or licences.

Remote data access means more flexibility and greater peace of mind for engineers and facilities managers, who no longer have to be on site to resolve an issue. If process variables go beyond set parameters and alarms go off, the device immediately notifies the person or team responsible and they can access live information. This should help them make informed decisions, regardless of where they are in the world.

Holistic approach
Before commissioning a harmonic filter for your application, it’s important to assess the entire system, calculate the harmonics and size the right solution for your specific set up. It is not enough to look at one troublesome application individually; instead, you need to look at the plant or entire operation as a whole. Often what looks like the problem can actually be an effect rather than a cause.

Companies should identify and understand all the components installed on site when it comes to both linear and non-linear loads. They should also be aware of the transformer size and the rated short-circuit breaking current. Only after understanding the system in its entirety, can a company make an informed decision on what type of harmonic filter it needs, as well as what capacity and additional features the filter should have.

CP Automation recommends performing a survey of the plant and capturing as much information as possible over several days. After this initial analysis, we can recommend the most appropriate product and install it without significant disruptions.

After the harmonic filter has been live for a several days, another survey should be performed to check if all problems have been resolved. This ensures the product is appropriate and it gives companies real peace of mind.

The increasing levels of harmonic currents in industrial and commercial applications are certainly an unintended consequence of rapid technology uptake. Luckily, like the Legionnaires disease bacteria problem, the solution is simple, sustainable and inexpensive. Moreover, if you’re unsure of what harmonic filter your system needs, help is never too far away.

October 20, 2015

When bigger means better


~ Business growth gets repair and replace specialist a new home ~

Supply and repair specialist stocks industrial automation equipmemt
Euroserv, the sister company of supply and repair specialist CP Automation, has expanded its North East office to a 6,200 square feet facility on the Armstrong Industrial Estate in Washington, near Newcastle upon Tyne. The new premises will allow Euroserv to stock, test and repair a larger number and variety of industrial automation equipment.

Euroserv specialises in the repair and new sales of robotic, CNC, servo, electric, spindle and axis motors, braking resistors, pumps, drives, encoders, harmonic filters and more. The company works with clients of all sizes in the North East area, from one-man bands to international leaders, such as Nissan and Rolls-Royce.

“This expansion will allow us to tap into new markets,” explains Martin McGuffie, service manager of Euroserv. “Our new workshop and warehouse facilities will house testing solutions for bigger equipment and more complex projects. The move allows us to make full use of our industry experience and turns Euroserv into a one-stop shop for industry in the area.”

Euroserv’s workshop is fully equipped with test and repair facilities for all types of industrial electrical equipment. The company also has the ability to re-magnetise magnets, returning them to full strength, which helps manufacturers reduce maintenance costs.


“Euroserv and CP Automation are helping industry cope with increasing financial pressure, especially when it comes to minimising downtime and reducing operations and management budgets,” points out Tony Young, director at CP Automation. “Increasing the space we operate in and improving our testing facilities emphasises our commitment to helping our customers across all industrial sectors.”  


December 12, 2014

Your new harmonic heroes


In 2014 supply, repair and field service specialist, CP Automation has seen a record level of applications in which its range of harmonic filters, including the active dynamic filter (ADF) range is required. 

The number and capacity of drives used in plant applications is increasing and with it rising levels of harmonics are beginning to play havoc in industry. The most common problems caused by harmonic currents include extreme stress on the electrical network, deterioration of the supply voltage quality and damage to equipment, all resulting in higher operating costs.

The powerful filters have a reduced footprint, which makes them perfect for ensuring power quality in office buildings, data handling centres, the mining industry, chemical plants and in any other industrial application where drives and motors are present.

To ensure these issues are avoided and the power quality in industrial environments remains optimal, active harmonic filters could be used. Comsys’ ADF series can handle any loss-creating behaviour in real time.

“We can’t stress enough how much of a positive impact the right harmonic filter can have on a company’s environmental performance, lowering energy consumption and improving productivity,” enthused John Mitchell, CP Automation’s business development manager.

“The industry still suffers from a piercing lack of awareness when it comes to harmonics; so working with a professional partner that takes the time to understand and evaluate your application before recommending a solution is crucial”.

The ADF series has a small footprint and a high power density, which makes it perfect for small and medium size commercial and industrial applications where space is precious.

The highlights this year are a 4 wire 100A unit, UL Certified models and increased power ratings by 20 per cent with new cooling techniques. A liquid cooled version of the harmonic filter range is also available, allowing a significant increase in power.

The modular design of the Comsys active harmonic filters allows sections to be removed and replaced without the need for a plethora of connectors and cables. This makes the product quick and easy to install, without having to shut down the operation. They lack of cables also makes the product simple to maintain, while significantly reducing costs.

If, for any reason, one of the power modules has a fault, the user can shut it down, while continuing to run the active filter in reduction mode. This will keep plant harmonics low, while allowing time for the necessary maintenance.
Bookmark and Share

November 13, 2014

Automation supply prioritises trust

Customers of the automation supply and maintenance firm, CP Automation, can now enjoy a whole host of new features and information at their fingertips thanks to the launch of its new website. The UK firm's new website, not only provides detailed product information but also allows the customer to buy there and then with a heavy emphasis on trustworthy supply. 

While it's not difficult to buy a motor, inverter or PLC online, trustworthy online purchasing is a rarity. A lot of products for sale on the internet seem to come from the grey market, without a safety certificate or any guarantee of reliability.

CP Automation specialises in the sale, repair and maintenance of industrial electronic boards, PLC's, AC drives, resistors, DC drives and inverters.


The product range extends from simple general purpose drives to mission critical systems requiring uncompromising control, enhanced intelligence, and high-speed communications capability.

The new site provides more detailed information on the products CP Automation integrates, with individual downloadable product spec sheets. The company's brochures are segregated into product types and are also downloadable from the site.

After the customer has found the information they need to make a buying decision, they then have the option of making a purchase from the online shop. CP Automation's online buying function stands out in the automation maintenance and supply industry, in which ecommerce is a rarity.  

"The new website provides an abundance of relevant information and allows customers to ask specific questions with our new feedback feature," explained Tony Young, a director of CP Automation.

"Our new products are highlighted on the home page and links to our blog keep visitors up to date with new developments. I think it's interesting that even though many automation components have almost become commodities, particularly in the replacement market, very few businesses have invested in e-commerce.

"The consumer  and more advanced B2B markets are already developing and using mCommerce (mobile commerce) solutions and yet few people in engineering are thinking on that level yet.

"It's ironic that the automation sector has countless mobile monitoring and bring-your-own-device apps, for everything from simple inverter or PLC communications all the way to SCADA and DCS management, and yet it's still difficult to buy a trustworthy motor online."

The new website comes just months after the company opened a branch in South Africa after receiving a record number of inquiries coming from the Sub Saharan continent. Bookmark and Share

August 14, 2014

British automation firm opens South African branch


In February, UK automation maintenance and supply firm CP Automation opened a branch in South Africa after receiving a record number of inquiries coming from the Sub Saharan continent. 

CP Automation specialises in the supply of complimentary products to Variable Speed Drives applications, repair and field service of industrial electronic boards, PLC's, AC drives, resistors, DC drives and inverters.

"We've had a good number of enquiries for high power applications such as hoists, steel mills and mining from Africa," explained Tony Young, a director CP Automation.  "The opportunities have reached a level that meant we really needed a local presence so we can make the most of this new market.

"The great thing is that we are entering a growing economy that has huge potential in the global market. There is a lot of scope to sell our products and the newly appointed country manager, Jim Rosser, formerly of Rockwell will make the South African branch a success," concluded Young.

The company believes that the new venture will complement its European business and hopes to establish long term relationships with South African partners.

"The key to success in any new country is to establish a network of local partners and create a robust supply chain,” commented John Mitchell, business development manager.  “We also believe our product and service offering differs greatly from one geographic location to another.

"For instance, in Europe we mostly deal with high speed OEMS, the African industry is powered by significantly larger applications. This means that the requirements will be different, but we want to ensure the end users get the right support,” he added.

CP Automation's core strength is supplying universal peripheral equipment to drive applications including dynamic braking resistors, regenerative units, brake choppers and harmonic filters. Passive devices such as line chokes, sine wave filters and EMC (Electromagnetic Compliance) filters are also part of CPA South Africa's offering.

CP Automation's new customers can expect a wide range of products from British and European suppliers from Cressall Resistors, Re-Spa, Chiaravalli, TAE Pickatron to Comsys, Roxburgh and RevCon.

Bookmark and Share

August 11, 2014

Whitepaper targets harmonic mitigation


Industrial component specialist, CP Automation, has made available for download a new whitepaper that addresses a lack of industry awareness of different methods of harmonic mitigation. It is designed to educate engineers on the most appropriate solutions to mitigate the damage caused by harmonic currents and utility level voltage distortion. 

Authored by Jonas Persson, product manager at Comsys AB, the paper highlights the challenges facing original equipment manufacturers (OEMs) in tackling the growing problem of harmonic currents. For many years this has held the industry back; the fact that engineers struggle to identify the best solutions for their needs due to a lack of information. The overall context is to reduce harmonic loading in a drive system.

The whitepaper details the four main mitigation techniques and their associated technologies. Covering series passive, series active, shunt passive and shunt active solutions, it presents in-depth case studies of real life implementations of each as well as theoretical worked examples explaining the benefits and drawbacks.

Knowing the different types of mitigation technique to employ is essential. There are three variations of the series-passive solution alone, line reactors, series harmonic filters and multi-phase, each with their own strengths and weaknesses. Choosing one over another is a decision that must be made from an informed perspective.

“Without both breadth and depth of knowledge, it is possible that the most efficient method of harmonic mitigation is being overlooked,” says John Mitchell, business development manager at CP Automation. “On top of that, there are numerous other challenges faced by engineers caused by the rise of non-linear loads, such as extra stresses on outdated equipment.”

“We hope this whitepaper will go some way to addressing the lack of information issue, which in turn will go some way to reducing the amount of harmonics related problems the wider engineering community encounters in electrical industry applications.”


To download the new whitepaper on mitigating harmonic currents, visit http://goo.gl/ikulpI
Bookmark and Share